Linear stage

Stage block supporting long strokes

Type for long-distance transport of linear stages, designed to pursue cost-efficiency

  • Maximum stroke: 21.3 m
  • Low cost
  • High speed

Features

Ideal for high-speed and long-distance transport applications

  • Effective stroke
    2,580 to 21,300 mm (coreless 95 N/200 N type)
    2,380 to 21,100 mm (core 250 N type)
  • Maximum allowable speed
    5 m/sec (coreless 95 N/200 N type)
    2.67 m/sec (core 250 N type)
  • The positioning detection method can be selected from an incremental linear encoder or a scale-less linear sensor.
  • Supports SSCNET III/H, CC-Link, EtherCAT, and MECHATROLINK-III

Video

High-speed, long-distance transport 1-axis linear stage

Specifications

Long stroke-supporting stage block individual Specifications

ModelNST-NA258D2ANNA402D2ANNA546D2ANNA690D2ANNA834D2ANNA978D2ANNA1122D2ANNA1266D2ANNA1410D2ANNA1554D2ANNA1698D2ANNA1842D2ANNA1986D2ANNA2130D2ANNA
Effective strokemm2,5804,0205,4606,9008,3409,78011,22012,66014,10015,54016,98018,42019,86021,300
Rated thrustN9595959595959595959595959595
Maximum thrustN275275275275275275275275275275275275275275
Linear servo motor typeCoreless
Encoder typeSelect from scale-less linear sensor/incremental linear encoder
Encoder resolutionμm4.88 (for scale-less linear sensor)/1 (for incremental linear encoder)
Maximum allowable speedm/sec5 (for scale-less linear sensor)/4.16 (for incremental linear encoder)
Repeated positioning accuracy*1μm±10 (for scale-less linear sensor)/±2 (for incremental linear encoder)
Lost motion*1μm1010101010101010101010101010
Maximum allowable load*2kg200200200200200200200200200200200200200200
Paired driver model
VPH SeriesNCR-H□2401A-B-□□□2401A-B-□□□2401A-B-□□□2401A-B-□□□2401A-B-□□□2401A-B-□□□2401A-B-□□□2401A-B-□□□2401A-B-□□□2401A-B-□□□2401A-B-□□□2401A-B-□□□2401A-B-□□□2401A-B-□□□

*1 The repeated positioning accuracy and the lost motion depend on the encoder resolution.
*2 The load must be evenly distributed.

Common specifications

Ambient temperature for use25℃±5℃
*Accuracy cannot be guaranteed outside of the above environment.
*Positioning accuracy, repeated positioning accuracy, and lost motion are guaranteed only when the temperature is constant at 22°C.
Ambient humidity for use85%RH or less, no condensation allowed
Installation locationAvoid any harmful atmosphere including corrosive gas, grinding oil, metal dust, and oil.
Indoors, away from direct sunlight.
Installation directionTable horizontal and facing upward
Cooling methodNatural cooling
Surface finish*1 *2Base and table: White anodizing
Sea levelSea level: 1,000 m or less

*1 The bottom and top surfaces of the base are untreated.
*2 Unless otherwise specified, appropriate rust prevention treatment will be applied.